IP30, Industrial 4-Port 10/100TX POE PSE + 1-Port Coax/UTP Long Reach POE Extender, -20 to 70 degrees C

Descrizione

One Power Sourcing for Multi Powered Devices Solution
PLANET Long Reach PoE solution is designed to extend IP Ethernet transmission and inject power simultaneously into a remote 802.3af/at PoE compliant powered device (PD) beyond the 100 meters distance limit of Ethernet. The solution works in pairs for point to point and point to multi-point connectivities.

Point to Multi Points
Type 1: Remote LRP Power through BNC/RJ45 with DC 56V input
The LRP-101 Injector, powered by IEEE 802.3at/af PoE or DC power adapter, transmits data and power over coaxial/ UTP cable to the LRP-104CET extender. An IEEE 802.3at/af compliant PoE PD will then automatically be powered by the LRP-104CET via UTP cabling.

LRP 104CET EMQ 1 1 L

Type 2: Local Power with External DC Input (DC 24V~48V)
The LRP-101 Injector, powered by IEEE 802.3at/af PoE or DC power adapter, transmits data through coaxial/ UTP cable to the LRP-104CET extender powered by external DC power. An IEEE 802.3at/af compliant PoE PD will then automatically be powered by the LRP-104CET via UTP cabling.

LRP 104CET EMQ 1 2 L

Multi Points to Multi Points:
Type 1: Remote LRP Power through BNC with DC 56V input
The LRP Switch, powered by itself, transmits data and power over coaxial cable to the LRP-104CET extender. An IEEE 802.3at/af compliant PoE PD will then automatically be powered by the LRP-104CET via UTP cabling.

LRP 104CET EMQ 5 1 L

Type 2: Local Power with External DC input (DC 24V~48V)
Powered by external DC power, the LRP Switch transmits data through coaxial cable to the LRP-104CET extender. An IEEE 802.3at/af compliant PoE PD will then automatically be powered by the LRP-104CET via UTP cabling.

LRP 104CET EMQ 5 2 L 1

Hardware Specifications
Ethernet Interface ■ Copper Ports
• Four 10/100BASE-TX RJ45 auto-MDI/MDI-X■ PoE Injector Ports
• Four ports with 802.3at/af PoE injector function with Port-1 to Port-4

■ Functionality
• Four DIP switches to control PoE output on or off with Port-1 to Port-4

■ PoE Standards Compliance
• IEEE 802.3at Power over Ethernet Plus/PSE

■ PoE Type
• End-span

■ PoE Power output
• 52V DC, PoE output depends on LRP Injector or LRP Switch
• 52V DC, 25 watts per port (external DC input)

■ Cabling
• Ethernet: 10BASE-T: 2-pair UTP Cat.3, 4 and 5
• Ethernet: 100BASE-TX: 2-pair UTP Cat.5, 5e and 6

■ Maximum Distance
• 100m

■ Maximum Frame size
• 1522 bytes

Long Reach PoE Interface ■ Connectivity
• One BNC female Long Reach PoE over Coaxial PD
• One RJ45 connector Long Reach PoE over UTP PD■ Power Input
• 44~ 56V DC

■ Power Pin Assignment
• BNC center pole: DC+
• BNC shield: DC-
• RJ45 Pins 1, 3, 5, 7: VCC+
• RJ45 Pins 2, 4, 6, 8: VCC-

■ Cabling
• Coaxial cable: 75 ohm
• RG-6/U cable, less than12Ω/1000 ft.
• RG-59/U cable, less than 30Ω/1000 ft.
• Cat. 3, 4, 5, 5e UTP cable (100 meters, max.)
• EIA/TIA-568 100-ohm STP (100 meters, max.)

■ Maximum Distance
• Coaxial
– Max. 200m with PoE+ output (656ft.)
– Max. 1000m with PoE output (3,280ft.)
• UTP
– Max. 500m with PoE+ output (1,640ft.)

■ Long Reach Ethernet Stan dard
• IEEE 1901

■ Modulation Type
• Wavelet-OFDM

■ Security
• 128-bit AES encryption

■ Frequency Band
• 2 ~ 28 MHz

■ Encryption
• AES 128-bit

■ LRP Compatibility
• With power over coaxial input
– LRP-101CH – 1-Port LRP Injector
– LRP-822CS – 8-Port LRP over Coax Switch
– LRP-1622CS – 16-Port LRP over Coax Switch
• With power over UTP input
– LRP-101UH – 1-Port LRP Injector

LED Indicator 3 x LED for External Power Supply:
DC Power 1 (Green)
DC Power 2 (Green)
Power Fault ( Red )
4 x LED for PoE Usage:
10W/20W/30W/40W (Green)
2 x LED for Long Reach PoE In:
PWR (Green)
LNK (Green)
2 x LED for each RJ45 interface (Port-1 and Port-4)
10/100Mbps LNK/ACT (Green)
PoE-in-use (Orange)
Installation DIN rail kit and wall-mount kit
Dimensions (W x D x H) 135 x 87.8 x 56 mm
Weight 644g
Power Requirements 44~56V DC power over coaxial input
DC 24~48V, redundant power with polarity reverses protection function
Power Consumption/Dissipation 130 watts/446BTU (Ethernet with PoE Full Loading)
Alarm One relay output for power failure. Alarm relay current carry ability: 1A @ 24V DC
Enclosure Aluminum case
Standards Conformance
Standards Compliance IEEE 802.3 Ethernet/10BASE-T
IEEE 802.3u Fast Ethernet/100BASE-TX
IEEE 802.3x Full-Duplex Flow Control
IEEE 802.3at Power over Ethernet Plus
Regulatory Compliance FCC Part 15 Class A, CE
Stability Testing IEC60068-2-32 (free fall)
IEC60068-2-27 (anti-shock)
IEC60068-2-6 (anti-vibration)
Environment
Temperature Operating: -20~70 degrees C
Storage: -25~75 degrees C
Humidity Operating: 5~95% (non-condensing)
Storage: 5~95% (non-condensing)
Performance
Coaxial Performance
Distance
Data Rate
(Upload/Download)
802.3af/at PoE Total Output Capability
Remote LRP Power through BNC W/56VDC IN
Remote LRP Power by LRP-822CS/LRP-1622CS
Local DC Power through Terminal Block
200m
91/88 Mbps
24W
18W/19W
120W
400m
89/87 Mbps
21W
14W/16W
120W
600m
83/81 Mbps
15W
10W/12W
120W
800m
68/69 Mbps
11W
7W/8W
120W
1000m
57/60 Mbps
8W
120W
UTP Performance
Distance
Data Rate
(Upload/Download)
802.3af/at PoE Total Output Capability
Remote LRP Power through RJ45 W/56VDC IN
Local DC Power through Terminal Block
100m
90/87Mbps
24W
120W
200m
76/77Mbps
21W
120W
300m
54/61Mbps
20W
120W
400m
39/47Mbps
20W
120W
500m
14/18Mbps
20W
120W

*As there are various resistance values in the category of RG-59/U or RG-6/U cable, the actual data rate will vary on the quality of the copper wire and environmental factors.